Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 16.323
1.
BMC Oral Health ; 24(1): 545, 2024 May 10.
Article En | MEDLINE | ID: mdl-38730391

BACKGROUND: This Finite Element Analysis was conducted to analyze the biomechanical behaviors of titanium base abutments and several crown materials with respect to fatigue lifetime and stress distribution in implants and prosthetic components. METHODS: Five distinct designs of implant-supported single crowns were modeled, including a polyetheretherketone (PEEK), polymer-infiltrated ceramic network, monolithic lithium disilicate, and precrystallized and crystallized zirconia-reinforced lithium silicates supported by a titanium base abutment. For the static load, a 100 N oblique load was applied to the buccal incline of the palatal cusp of the maxillary right first premolar. The dynamic load was applied in the same way as in static loading with a frequency of 1 Hz. The principal stresses in the peripheral bone as well as the von Mises stresses and fatigue strength of the implants, abutments, prosthetic screws, and crowns were assessed. RESULTS: All of the models had comparable von Mises stress values from the implants and abutments, as well as comparable maximum and minimum principal stress values from the cortical and trabecular bones. The PEEK crown showed the lowest stress (46.89 MPa) in the cervical region. The prosthetic screws and implants exhibited the highest von Mises stress among the models. The lithium disilicate crown model had approximately 9.5 times more cycles to fatique values for implants and 1.7 times more cycles to fatique values for abutments than for the lowest ones. CONCLUSIONS: With the promise of at least ten years of clinical success and favorable stress distributions in implants and prosthetic components, clinicians can suggest using an implant-supported lithium disilicate crown with a titanium base abutment.


Benzophenones , Crowns , Dental Abutments , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Finite Element Analysis , Titanium , Titanium/chemistry , Humans , Dental Porcelain/chemistry , Polyethylene Glycols/chemistry , Dental Materials/chemistry , Polymers , Ketones/chemistry , Zirconium/chemistry , Dental Implants, Single-Tooth , Materials Testing , Dental Implant-Abutment Design , Biomechanical Phenomena
2.
Food Res Int ; 186: 114372, 2024 Jun.
Article En | MEDLINE | ID: mdl-38729730

The oxidation and degradation of fats lead to a decrease in the nutritional value of food and pose safety concerns. Saturated fatty acids also hold a significant position in the field of lipid oxidation. In this study, the oxidation products of methyl palmitate were investigated by using gas chromatography mass spectrometry (GC-MS). Seven monohydroperoxides and 72 secondary oxidation products were detected. Combined with density functional theory (DFT) calculations, the formation mechanisms of oxidation products can be summarized into four stages. The initial stage involved the formation of monohydroperoxides and alkanes, followed by the subsequent stage involving methyl x-oxo(hydroxy)hexadecanoates. The third stage involved the formation of methyl ketones, carboxylic acids, and aldehydes, while the final stage involved lactones. Meanwhile, methyl ketones were the most abundant oxidation product, approximately 25 times more abundant than aldehydes; the calculated results agreed well with the experimental results. The establishment of a comprehensive thermal oxidation mechanism for palmitic acid provided a new foundation for future lipid oxidation analyses.


Gas Chromatography-Mass Spectrometry , Hot Temperature , Oxidation-Reduction , Aldehydes/chemistry , Aldehydes/analysis , Palmitates/chemistry , Palmitic Acid/chemistry , Ketones/chemistry , Carboxylic Acids/chemistry
3.
PLoS One ; 19(5): e0301041, 2024.
Article En | MEDLINE | ID: mdl-38701088

OBJECTIVE: To evaluate the safety and performance of an implantable near-infrared (NIR) spectroscopy sensor for multi-metabolite monitoring of glucose, ketones, lactate, and ethanol. RESEARCH DESIGN AND METHODS: This is an early feasibility study (GLOW, NCT04782934) including 7 participants (4 with type 1 diabetes (T1D), 3 healthy volunteers) in whom the YANG NIR spectroscopy sensor (Indigo) was implanted for 28 days. Metabolic challenges were used to vary glucose levels (40-400 mg/dL, 2.2-22.2 mmol/L) and/or induce increases in ketones (ketone drink, up to 3.5 mM), lactate (exercise bike, up to 13 mM) and ethanol (4-8 alcoholic beverages, 40-80g). NIR spectra for glucose, ketones, lactate, and ethanol levels analyzed with partial least squares regression were compared with blood values for glucose (Biosen EKF), ketones and lactate (GlucoMen LX Plus), and breath ethanol levels (ACE II Breathalyzer). The effect of potential confounders on glucose measurements (paracetamol, aspartame, acetylsalicylic acid, ibuprofen, sorbitol, caffeine, fructose, vitamin C) was investigated in T1D participants. RESULTS: The implanted YANG sensor was safe and well tolerated and did not cause any infectious or wound healing complications. Six out 7 sensors remained fully operational over the entire study period. Glucose measurements were sufficiently accurate (overall mean absolute (relative) difference MARD of 7.4%, MAD 8.8 mg/dl) without significant impact of confounders. MAD values were 0.12 mM for ketones, 0.16 mM for lactate, and 0.18 mM for ethanol. CONCLUSIONS: The first implantable multi-biomarker sensor was shown to be well tolerated and produce accurate measurements of glucose, ketones, lactate, and ethanol. TRIAL REGISTRATION: Clinical trial identifier: NCT04782934.


Ethanol , Feasibility Studies , Ketones , Lactic Acid , Spectroscopy, Near-Infrared , Humans , Ketones/analysis , Male , Ethanol/analysis , Spectroscopy, Near-Infrared/methods , Adult , Female , Lactic Acid/analysis , Lactic Acid/blood , Blood Glucose/analysis , Middle Aged , Diabetes Mellitus, Type 1/blood , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Glucose/analysis
5.
BMC Oral Health ; 24(1): 523, 2024 May 03.
Article En | MEDLINE | ID: mdl-38702708

BACKGROUND: The rising demand for improved aesthetics has driven the utilization of recently introduced aesthetic materials for creating custom post and core restorations. However, information regarding the fracture resistance of these materials remains unclear, which limits their practical use as custom post and core restorations in clinical applications. AIM OF THE STUDY: This study aimed to evaluate the fracture resistance of three non-metallic esthetic post and core restorations and their modes of failure. MATERIALS AND METHODS: Thirty-nine single-rooted human maxillary central incisors were endodontically treated. A standardized post space preparation of 9mm length was performed to all teeth to receive custom-made post and core restorations. The prepared teeth were randomly allocated to receive a post and core restoration made of one of the following materials (n=13): glass fiber-reinforced composite (FRC), polyetheretherketone (PEEK) and polymer-infiltrated ceramic-network (PICN). An intraoral scanner was used to scan all teeth including the post spaces. Computer-aided design and computer-aided manufacturing (CAD-CAM) was used to fabricate post and core restorations. Post and core restorations were cemented using self-adhesive resin cement. All specimens were subjected to fracture resistance testing using a universal testing machine. Failure mode analysis was assessed using a stereomicroscope and SEM. The data was statistically analyzed using One-Way ANOVA test followed by multiple pairwise comparisons using Bonferroni adjusted significance level. RESULTS: Custom PEEK post and core restorations displayed the least fracture load values at 286.16 ± 67.09 N. In contrast, FRC exhibited the highest average fracture load at 452.60 ± 105.90 N, closely followed by PICN at 426.76 ± 77.99 N. In terms of failure modes, 46.2% of specimens with PICN were deemed non-restorable, while for PEEK and FRC, these percentages were 58.8% and 61.5%, respectively. CONCLUSIONS: Within the limitation of this study, both FRC and PICN demonstrated good performance regarding fracture resistance, surpassing that of PEEK.


Composite Resins , Computer-Aided Design , Dental Restoration Failure , Esthetics, Dental , Post and Core Technique , Humans , Ceramics , Dental Stress Analysis , Benzophenones , Incisor/injuries , Dental Materials/chemistry , Polyethylene Glycols , Ketones/chemistry , Polymers , Glass , Materials Testing , Dental Prosthesis Design
6.
BMC Oral Health ; 24(1): 513, 2024 May 02.
Article En | MEDLINE | ID: mdl-38698366

BACKGROUND: This study aims to evaluate the effect of surface treatment and resin cement on the shear bond strength (SBS) and mode of failure of polyetheretherketone (PEEK) to lithium disilicate ceramic (LDC). This is suggested to study alternative veneering of PEEK frameworks with a ceramic material. METHODS: eighty discs were prepared from PEEK blank and from lithium disilicate ceramic. Samples were divided into four groups according to surface treatment: Group (A) air abraded with 110 µm Al2O3, Group (AP) air abrasion and primer application, Group (S) 98% sulfuric acid etching for 60 s, Group (SP) Sulfuric acid and primer. Each group was subdivided into two subgroups based on resin cement type used for bonding LDC:1) subgroup (L) self- adhesive resin cement and 2) subgroup (B) conventional resin cement (n = 10). Thermocycling was done for all samples. The bond strength was assessed using the shear bond strength test (SBS). Failure mode analysis was done at 50X magnification with a stereomicroscope. Samples were chosen from each group for scanning electron microscope (SEM). The three-way nested ANOVA followed by Tukey's post hoc test were used for statistical analysis of results. Comparisons of effects were done utilizing one way ANOVA and (p < 0.05). RESULTS: The highest mean of shear bond strength values was demonstrated in Group of air abrasion with primer application using conventional resin cement (APB) (12.21 ± 2.14 MPa). Sulfuric acid groups showed lower shear bond strength values and the majority failed in thermocycling especially when no primer was applied. The failure mode analysis showed that the predominant failure type was adhesive failure between cement and PEEK, while the remaining was mixed failure between cement and PEEK. CONCLUSION: The air abrasion followed by primer application and conventional resin cement used for bonding Lithium Disilicate to PEEK achieved the best bond strength. Primer application did not have an effect when self-adhesive resin cement was used in air-abraded groups. Priming step is mandatory whenever sulfuric acid etching surface treatment is utilized for PEEK.


Benzophenones , Dental Bonding , Dental Porcelain , Dental Stress Analysis , Ketones , Materials Testing , Polyethylene Glycols , Polymers , Resin Cements , Shear Strength , Surface Properties , Dental Bonding/methods , Acid Etching, Dental/methods , Sulfuric Acids , Ceramics/chemistry , Air Abrasion, Dental/methods , Aluminum Oxide , Dental Veneers , Dental Etching/methods , Humans
7.
Cells ; 13(8)2024 Apr 09.
Article En | MEDLINE | ID: mdl-38667271

Even with the best infection control protocols in place, the risk of a hospital-acquired infection of the surface of an implanted device remains significant. A bacterial biofilm can form and has the potential to escape the host immune system and develop resistance to conventional antibiotics, ultimately causing the implant to fail, seriously impacting patient well-being. Here, we demonstrate a 4 log reduction in the infection rate by the common pathogen S. aureus of 3D-printed polyaryl ether ketone (PAEK) polymeric surfaces by covalently binding the antimicrobial peptide Mel4 to the surface using plasma immersion ion implantation (PIII) treatment. The surfaces with added texture created by 3D-printed processes such as fused deposition-modelled polyether ether ketone (PEEK) and selective laser-sintered polyether ketone (PEK) can be equally well protected as conventionally manufactured materials. Unbound Mel4 in solution at relevant concentrations is non-cytotoxic to osteoblastic cell line Saos-2. Mel4 in combination with PIII aids Saos-2 cells to attach to the surface, increasing the adhesion by 88% compared to untreated materials without Mel4. A reduction in mineralisation on the Mel4-containing surfaces relative to surfaces without peptide was found, attributed to the acellular portion of mineral deposition.


Antimicrobial Peptides , Benzophenones , Polymers , Printing, Three-Dimensional , Prostheses and Implants , Staphylococcus aureus , Humans , Staphylococcus aureus/drug effects , Antimicrobial Peptides/pharmacology , Antimicrobial Peptides/chemistry , Antimicrobial Peptides/metabolism , Prostheses and Implants/adverse effects , Polymers/chemistry , Polymers/pharmacology , Biofilms/drug effects , Ketones/chemistry , Ketones/pharmacology , Osteoblasts/drug effects , Osteoblasts/metabolism , Polyethylene Glycols/chemistry , Polyethylene Glycols/pharmacology , Surface Properties , Bone and Bones/drug effects , Bone and Bones/metabolism , Orthopedics
8.
J Med Chem ; 67(9): 7146-7157, 2024 May 09.
Article En | MEDLINE | ID: mdl-38636481

Previously, we demonstrated that linear peptide epoxyketones targeting the immunoproteasome (iP) could ameliorate cognitive deficits in mouse models of Alzheimer's disease (AD) independently of amyloid deposition. We also reported the first iP-targeting macrocyclic peptide epoxyketones, which exhibit improved metabolic stability compared with their linear counterparts. Here, we prepared additional macrocyclic peptide epoxyketones and compared them with existing macrocyclic iP inhibitors by assessing Caco2 cell-based permeability and microsomal stability, providing the four best macrocyclic iP inhibitors. We then evaluated the four compounds using the Ames test and the potency assays in BV2 cells, selecting compound 5 as our AD drug lead. When 5 was administered intravenously (40 mg/kg) or orally (150 mg/kg) into healthy BALB/c mice, we observed considerable iP inhibition in the mouse brain, indicating good blood-brain barrier permeability and target engagement. Combined results suggest that 5 is a promising AD drug lead that may need further investigation.


Alzheimer Disease , Blood-Brain Barrier , Brain , Mice, Inbred BALB C , Animals , Alzheimer Disease/drug therapy , Alzheimer Disease/metabolism , Humans , Blood-Brain Barrier/metabolism , Mice , Caco-2 Cells , Brain/metabolism , Proteasome Endopeptidase Complex/metabolism , Permeability , Peptides, Cyclic/chemistry , Peptides, Cyclic/pharmacology , Peptides, Cyclic/pharmacokinetics , Proteasome Inhibitors/pharmacology , Proteasome Inhibitors/chemistry , Macrocyclic Compounds/chemistry , Macrocyclic Compounds/pharmacology , Macrocyclic Compounds/pharmacokinetics , Ketones/chemistry , Ketones/pharmacology , Structure-Activity Relationship
9.
Arch Orthop Trauma Surg ; 144(5): 2067-2076, 2024 May.
Article En | MEDLINE | ID: mdl-38642161

BACKGROUND: Polyaryl-ether-ether-ketone (PEEK) has gained popularity as a substrate for orthopaedic hardware due to its desirable properties such as heat and deformation resistance, low weight, and ease of manufacturing. However, we observed a relatively high failure rate of PEEK-based hinges in a distal femur reconstruction system. In this study, we aimed to evaluate the proportion of patients who experienced implant failure, analyse the mechanism of failure, and document the associated clinical findings. METHODS: We conducted a retrospective cohort study, reviewing the medical charts of 56 patients who underwent distal femur resection and reconstruction with a PEEK Optima hinge-based prosthesis between 2004 and 2018. Concurrently, we performed a clinical and biomechanical failure analysis. RESULTS: PEEK component failure occurred in 21 out of 56 patients (37.5%), with a mean time to failure of 63.2 months (range: 13-144 months, SD: 37.9). The survival distributions of PEEK hinges for males and females were significantly different (chi-square test, p-value = 0.005). Patient weight was also significantly associated with the hazard of failure (Wald's test statistic, p-value = 0.031). DISCUSSION: Our findings suggest that PEEK hinge failure in a distal femur reconstruction system is correlated with patient weight and male gender. Retrieval analysis revealed that failure was related to fretting and microscopic fractures due to cyclic loading, leading to instability and mechanical failure of the PEEK component in full extension. Further assessment of PEEK-based weight bearing articulating components against metal is warranted.


Benzophenones , Femur , Ketones , Polyethylene Glycols , Polymers , Prosthesis Design , Prosthesis Failure , Humans , Male , Female , Retrospective Studies , Middle Aged , Aged , Femur/surgery , Adult , Aged, 80 and over
10.
Nutrients ; 16(7)2024 Mar 23.
Article En | MEDLINE | ID: mdl-38612966

Relative to carbohydrate (CHO) alone, exogenous ketones followed by CHO supplementation during recovery from glycogen-lowering exercise have been shown to increase muscle glycogen resynthesis. However, whether this strategy improves subsequent exercise performance is unknown. The objective of this study was to assess the efficacy of ketone monoester (KME) followed by CHO ingestion after glycogen-lowering exercise on subsequent 20 km (TT20km) and 5 km (TT5km) best-effort time trials. Nine recreationally active men (175.6 ± 5.3 cm, 72.9 ± 7.7 kg, 28 ± 5 y, 12.2 ± 3.2% body fat, VO2max = 56.2 ± 5.8 mL· kg BM-1·min-1; mean ± SD) completed a glycogen-lowering exercise session, followed by 4 h of recovery and subsequent TT20km and TT5km. During the first 2 h of recovery, participants ingested either KME (25 g) followed by CHO at a rate of 1.2 g·kg-1·h-1 (KME + CHO) or an iso-energetic placebo (dextrose) followed by CHO (PLAC + CHO). Blood metabolites during recovery and performance during the subsequent two-time trials were measured. In comparison to PLAC + CHO, KME + CHO displayed greater (p < 0.05) blood beta-hydroxybutyrate concentration during the first 2 h, lower (p < 0.05) blood glucose concentrations at 30 and 60 min, as well as greater (p < 0.05) blood insulin concentration 2 h following ingestion. However, no treatment differences (p > 0.05) in power output nor time to complete either time trial were observed vs. PLAC + CHO. These data indicate that the metabolic changes induced by KME + CHO ingestion following glycogen-lowering exercise are insufficient to enhance subsequent endurance time trial performance.


Glycogen , Nutritional Status , Male , Humans , 3-Hydroxybutyric Acid , Ketones , Eating
11.
Nutrients ; 16(7)2024 Apr 06.
Article En | MEDLINE | ID: mdl-38613113

The implications of soy consumption on human health have been a subject of debate, largely due to the mixed evidence regarding its benefits and potential risks. The variability in responses to soy has been partly attributed to differences in the metabolism of soy isoflavones, compounds with structural similarities to estrogen. Approximately one-third of humans possess gut bacteria capable of converting soy isoflavone daidzein into equol, a metabolite produced exclusively by gut microbiota with significant estrogenic potency. In contrast, lab-raised rodents are efficient equol producers, except for those raised germ-free. This discrepancy raises concerns about the applicability of traditional rodent models to humans. Herein, we designed a gnotobiotic mouse model to differentiate between equol producers and non-producers by introducing synthetic bacterial communities with and without the equol-producing capacity into female and male germ-free mice. These gnotobiotic mice display equol-producing phenotypes consistent with the capacity of the gut microbiota received. Our findings confirm the model's efficacy in mimicking human equol production capacity, offering a promising tool for future studies to explore the relationship between endogenous equol production and health outcomes like cardiometabolic health and fertility. This approach aims to refine dietary guidelines by considering individual microbiome differences.


Equol , Isoflavones , Humans , Female , Male , Animals , Mice , Disease Models, Animal , Ketones , Phenotype
12.
Dent Med Probl ; 61(2): 249-255, 2024.
Article En | MEDLINE | ID: mdl-38652924

BACKGROUND: As polyether ether ketone (PEEK) is a relatively new material in dentistry, its bonding properties with regard to dental acrylic base materials are not fully known. To ensure the long-term success of removable dentures with a PEEK framework, the base materials must be well bonded to each other. OBJECTIVES: The study aimed to investigate the effects of different kinds of surface roughening treatment on PEEK and acrylic resin bonding. MATERIAL AND METHODS: Eighty PEEK specimens (N = 80) were randomly divided into 5 groups (n = 16 per group) and subjected to various surface roughening treatment (control, grinding, sandblasting, tribochemical silica coating (CoJet), and sulfuric acid etching). Heat-polymerized acrylic resin was applied to the treated surfaces of the PEEK specimens. The shear bond strength (SBS) test, environmental scanning electron microscopy (ESEM) analysis and three-dimensional (3D) surface topography analysis were performed. The statistical analysis of the data was conducted using the analysis of variance (ANOVA) and Tukey's multiple comparison test. RESULTS: The one-way ANOVA showed significant differences in the SBS values between the groups (p = 0.001). Sandblasting, tribochemical silica coating and sulfuric acid etching resulted in high SBS values (p = 0.001). The highest SBS values were observed in the sulfuric acid etching group (8.83 ±3.63 MPa), while the lowest SBS values were observed in the control group (3.33 ±2.50 MPa). CONCLUSIONS: The additional roughening treatment applied to the PEEK surface increases the bond strength with heat-polymerized acrylic resin.


Acrylic Resins , Benzophenones , Dental Bonding , Ketones , Polyethylene Glycols , Polymers , Surface Properties , Pilot Projects , Ketones/chemistry , Polyethylene Glycols/chemistry , Acrylic Resins/chemistry , Microscopy, Electron, Scanning , Materials Testing , Humans , Shear Strength , Sulfuric Acids/chemistry , Dental Stress Analysis
13.
Medicine (Baltimore) ; 103(17): e38004, 2024 Apr 26.
Article En | MEDLINE | ID: mdl-38669369

This paper demonstrates a digital manufacturing technique of a removable orthodontic appliance from an intraoral scan. An intraoral scan was made for the maxillary and mandibular arches. 3Shape Orthodontics Appliance Designer produced the virtual Hawley retainer, consisting of alloy components (Adam Clasps and Fitted Labial bow) and a base plate. The base plate design was modified to adapt to inserting the alloy components, which were combined using cold-cured acrylic. The finished Hawley retainer was assessed intraorally. The described technique emphasizes the design specifications of digitally designed and manufactured removable orthodontic appliances. A combination of additive and subtractive techniques was successfully employed to manufacture the alloy components and base plate. This novel method provides an alternative approach to manufacturing removable appliances with computer-aided design (CAD)/computer-aided manufacturing (CAM) technologies. The described process offers a precursor to digital manufacturing of other developed designs of dental appliances.


Computer-Aided Design , Printing, Three-Dimensional , Humans , Orthodontic Appliance Design , Polymers , Benzophenones , Polyethylene Terephthalates , Ketones , Alloys , Orthodontic Appliances, Removable
14.
J Chem Inf Model ; 64(8): 3213-3221, 2024 Apr 22.
Article En | MEDLINE | ID: mdl-38591731

In this study, we devised a new method to predict facial selectivity by quantifying steric and orbital factors for the nucleophile approaching both π-plane faces. Using this method, we quantified the total electron density and frontier orbital distributions of 163 cyclic ketones with various structures and quantitatively explained the surface selectivity of 323 reactions with eight nucleophiles (BH3, LiAlH4, NaBH4, LiAl(OMe)3H, MeLi, MeMgI, PhLi, and PnMgI). Importance analysis showed a large orbital effect for BH3, LiAlH4, and NaBH4 and the dominance of the steric effect for LiAl(OMe)3H, MeLi, MeMgI, PhLi, and PhMgI. Our method analyzes three-dimensional features based on Gaussian cube files, which can be easily obtained using mainstream computational chemistry software packages, and this approach should prove useful for predicting the rates and facial selectivity of other reactions.


Ketones , Ketones/chemistry , Models, Molecular , Molecular Conformation
15.
ACS Synth Biol ; 13(4): 1100-1104, 2024 Apr 19.
Article En | MEDLINE | ID: mdl-38587465

A proline-based artificial enzyme is prepared by grafting the l-proline moieties onto the surface of bovine serum albumin (BSA) protein through atom transfer radical polymerization (ATRP). The artificial enzyme, the BSA-PolyProline conjugate, prefers to catalyze the formation of unsaturated ketones rather than ß-hydroxy ketones in the reaction between acetone and aldehydes, which is difficult to achieve in free-proline catalysis. The altered reaction selectivity is ascribed to the locally concentrated l-proline moieties surrounding the BSA molecule, indicating a microenvironmental effect-induced switching of the reaction mechanism. Taking advantage of this selectivity, we used this artificial enzyme in conjunction with a natural enzyme, old yellow enzyme 1 (OYE1), to demonstrate a simple synthesis of different aliphatic ketones from acetone and aldehydes via tandem catalysis.


Acetone , Ketones , Proline , Aldehydes , Catalysis , Stereoisomerism
16.
J Mech Behav Biomed Mater ; 154: 106539, 2024 Jun.
Article En | MEDLINE | ID: mdl-38598917

PURPOSE: Polyetheretherketone (PEEK) is considered as an alternative to metal material for removable partial denture (RPD). However, the retentive force is not strong as a metal RPD. This study investigated the retention and fatigue performance of PEEK clasps with different proportions of clasp arm engaging the undercut to verify a new strategy to improve their clinical performance. METHODS: Three groups (n = 10/group) of PEEK clasps with their terminal 1/3, 2/3 and the whole of retentive arms engaging the undercut were fabricated along with a group (n = 10) of conventional cobalt-chrome (CoCr) clasps as control group. Retentive forces were measured by universal testing machine initially and at an interval of 1500 cycles for a total of 15,000 fatigue cycles. The fatigue cycles were conducted by repeated insertion and removal of the clasp using fatigue testing machine. Each clasp was scanned by Trios3 scanner before and after fatigue test to obtain digital models. The deformation of the clasp was evaluated by root mean square (RMS) through aligning the two models in Geomagic wrap (2021). Scanning electron microscopy (SEM) and finite element analysis were carried out to observe the abrasion and the von Mises stress of the clasp arm. Kruskal-Wallis H test was used to compare the retentive forces and the RMSs of the studied groups followed by Bonferroni multiple comparisons. RESULTS: The whole of PEEK clasp arm engaging the undercut provided higher mean retentive forces (7.99 ± 2.02 N) than other PEEK clasp groups (P < 0.001) and was closer to CoCr clasps (11.88 ± 2.05 N). The RMSs of PEEK clasps were lower than CoCr clasps (P < 0.05) while the differences among PEEK clasps were of no statistical significance (P > 0.05). SEM showed that evidences of surface abrasion were observed on the section that engaged the undercut for all groups of clasps. The stress concentration mainly occurred on the initial part of the retentive arm. The maximum von Mises stress of each group was below the compressive strength of PEEK. CONCLUSIONS: Proportions of PEEK clasp arm engaging the undercut positively influenced the retentive force and the fatigue resistance of PEEK clasps was superior than CoCr clasps. It is a feasible method to improve the retention of PEEK clasps by increasing the proportion of clasp arm engaging the undercut. Clinical trials are needed to further verify this innovation.


Benzophenones , Denture Retention , Denture, Partial, Removable , Polyethylene Glycols , Polymers , Ketones , Chromium Alloys , Dental Stress Analysis , Dental Clasps
17.
BMJ Open Diabetes Res Care ; 12(2)2024 Apr 27.
Article En | MEDLINE | ID: mdl-38677719

Ketogenic diets have been widely used for weight loss and are increasingly used in the management of type 2 diabetes. Despite evidence that ketones have multiple positive effects on kidney function, common misconceptions about ketogenic diets, such as high protein content and acid load, have prevented their widespread use in individuals with impaired kidney function. Clinical trial evidence focusing on major adverse kidney events is sparse. The aim of this review is to explore the effects of a ketogenic diet, with an emphasis on the pleiotropic actions of ketones, on kidney health. Given the minimal concerns in relation to the potential renoprotective effects of a ketogenic diet, future studies should evaluate the safety and efficacy of ketogenic interventions in kidney disease.


Diabetes Mellitus, Type 2 , Diet, Ketogenic , Diet, Ketogenic/methods , Humans , Diabetes Mellitus, Type 2/diet therapy , Diabetic Nephropathies/diet therapy , Ketones , Kidney Diseases/diet therapy
18.
Chem Pharm Bull (Tokyo) ; 72(4): 413-420, 2024.
Article En | MEDLINE | ID: mdl-38684408

A diazo-, metal-, and base-free multi-substituted hydrazone synthesis via a formal reductive N-H bond insertion reactions of hydrazones to α-keto esters has been developed. The protocol features a broad substrate scope and good functional group tolerance, providing N-H bond insertion products in moderate to excellent yields. Moreover, P(III)-mediated N-H functionalization of pharmaceutical containing hydrazone moiety was also successfully achieved.


Esters , Hydrazones , Hydrazones/chemistry , Hydrazones/chemical synthesis , Esters/chemistry , Esters/chemical synthesis , Molecular Structure , Oxidation-Reduction , Ketones/chemistry , Ketones/chemical synthesis , Catalysis
19.
Am J Sports Med ; 52(6): 1428-1438, 2024 May.
Article En | MEDLINE | ID: mdl-38619003

BACKGROUND: Rotator cuff tears have been repaired using the transosseous method for decades. The direct suture (DS) technique has been widely used for rotator cuff tears; however, the retear rate is relatively high. Suture anchors are now used frequently for rotator cuff repair (RCR) in accordance with recent developments in materials. However, polyether ether ketone (PEEK) may still cause complications such as the formation of cysts and osteophytes. Some studies have developed the inlay suture (IS) technique for RCR. PURPOSE/HYPOTHESIS: To compare how 3 different surgical techniques-namely, the DS, IS, and PEEK suture anchor (PSA)-affect tendon-bone healing after RCR. We hypothesized that the IS technique would lead to better tendon-to-bone healing and that the repaired structure would be similar to the normal enthesis. STUDY DESIGN: Controlled laboratory study. METHODS: Acute infraspinatus tendon tears were created in 36 six-month-old male rabbits, which were divided into 3 groups based on the technique used for RCR: DS, IS, and PSA. Animals were euthanized at 6 and 12 weeks postoperatively and underwent a histological assessment and imaging. The expression of related proteins was demonstrated by immunohistochemistry and immunofluorescence staining. Mechanical properties were evaluated by biomechanical testing. RESULTS: At 12 weeks, regeneration of the enthesis was observed in the 3 groups. However, the DS group showed a lower type I collagen content than the PSA and IS groups, which was similar to the results for scleraxis. The DS group displayed a significantly inferior type II collagen expression and proteoglycan deposition after safranin O/fast green and sirius red staining. With regard to runt-related transcription factor 2 and alkaline phosphatase, the IS group showed upregulated expression levels compared with the other 2 groups. CONCLUSION: Compared with the DS technique, the PSA and IS techniques contributed to the improved maturation of tendons and fibrocartilage regeneration, while the IS technique particularly promoted osteogenesis at the enthesis. CLINICAL RELEVANCE: The IS and PSA techniques may be more beneficial for tendon-bone healing after RCR.


Benzophenones , Ketones , Polyethylene Glycols , Polymers , Rotator Cuff Injuries , Rotator Cuff , Suture Anchors , Suture Techniques , Animals , Rabbits , Male , Rotator Cuff Injuries/surgery , Rotator Cuff/surgery , Wound Healing , Disease Models, Animal
20.
BMC Oral Health ; 24(1): 444, 2024 Apr 12.
Article En | MEDLINE | ID: mdl-38609958

BACKGROUND: This study evaluated the shear bond strength (SBS) of two different polyetheretherketone (PEEK) and CAD-CAM materials after aging. METHODS: A total of 42 frameworks were designed and milled from 2 different PEEK discs (Copra Peek, P and BioHPP, B). P and B frameworks were divided into 3 subgroups (n = 7). 14 slices were prepared each from feldspathic ceramic (Vitablocs Mark II, VM), hybrid nanoceramic (Cerasmart, CS), and polymer-infiltrated ceramic (Vita Enamic, VE) blocks. After surface preparations, the slices were cemented to P and B surfaces. The samples were subjected to thermal aging (5000 cycles). SBS of all the samples was measured. Fractured surfaces were examined by SEM/EDX analysis. The Shapiro-Wilk, Two-way Robust ANOVA and Bonferroni correction tests were used to analyze the data (a = .05). RESULTS: Frameworks, ceramics, and frameworks x ceramics had significant differences (p < 0.05). The highest SBS value was seen in B-VM (p < 0.05). VM offered the highest SBS with both P and B. The differences between P-VM, P-CS, P-VE and B-CS and B-VE were insignificant (p > 0.05). According to EDX analysis, ytterbium and fluorine was seen in B content, unlike P. While VM and CS contained fluorine, barium, and aluminum; sodium and aluminum were observed in the VE structure. CONCLUSION: Bonding of P and B with VM offers higher SBS. VM, CS and VE did not make any difference in SBS for P, however VM showed a significant difference for B.


Aluminum , Benzophenones , Fluorine , Polymers , Humans , Polyethylene Glycols , Computer-Aided Design , Ketones
...